CICECO Aveiro |
NMR
|
Solid-State NMR: Bruker Avance 400 (9.4 T) wide-bore spectrometer, dedicated to solids; Bruker Avance 500 (11.7 T) narrow-bore spectrometer - a liquid-state machine upgraded with high-power amplifiers, MAS unit, etc, allowing solids work; main probes: MAS 2.5, 4 and 7 mm (up to 35 kHz spinning rates); 4 mm HR MAS, CRAMPS, static. In 1 year time both spectrometers will be equipped with a third X channel and triple-resonance probes. We are also getting a LC-NMR facility. |
|
|
CICECO Aveiro |
TEM
|
300 kV TEM Hitachi H9000-NA with 1.4 A resolution equipped with EDS (energy dispersive spectroscopy) system from Roentec, PEELS paralel electron energy loss spectrometry from GATAN, TV rate camera and low temperature (liq He) TEM sample stage. During 2005 will be installed a new 200kV TEM with Schottky emission gun (FEG) emission and STEM mode, equipped with EDS system. |
|
|
CICECO Aveiro |
SEM
|
FEG SEM Hitachi S4100 equipped with backscattered detector and EDS system. coming soon: new SEM with Schottky emission backscattered detector and EDS system. |
|
|
CICECO Aveiro |
PL
|
Photoluminescence (steady state and time-resolved): Modular double grating excitation spectrofluorimeter with a TRIAX 320 emission monochromator (Fluorolog-3, Jobin Yvon-Spex) coupled to a R928 (VIS) and to a H9170-75 (NIR) Hamamatsu photomultipliers.
Model: SPEX-JY-HORIBA, Fluorolog-3 (FL3 2T) |
|
|
CICECO Aveiro |
Raman
|
Bruker RFS100/s FT-Raman spectrometer (Nd:YAG laser, 1064 nm excitation); options: Variable temperature cell (298K - 150 K); Polarization analyser |
|
|
LCMC Paris |
NMR
|
Solid state NMR: 300 and 400 Mhz WB spectrometers equipped with 3 channels; Probe heads : CP-MAS 7 mm, 4 mm and 2.5 mm; Triple resonance (ask for details) |
|
|
ISM Bordeaux |
DSC
|
Perkin DSC7; Determination of phase transition temperatures (melting, Tg, etc?) Determination of enthalpies |
|
|
LOMA Bordeaux |
PL
|
High sensitivity optical femtosecond spectroscopy in the near IR (800nm): Pump-probe time-resolved spectroscopy with 10-7 sensitivity; 15 fs time-resolution (home made system) The experiments are run at room temperature. |
|
|
LOMA Bordeaux |
PL
|
optical femtosecond spectroscopy: Pump-probe spectroscopy in UV-near IR range; 80MHz-150 kHz repetition rate; 50 fs time-resolution (home made system): Two pump-probe set-up will be running. The first one will be dedicated to the UV and IR spectral range. The second will be dedicated to the Near IR pump and far IR probe experiments. A nitrogen cryostat iw available. Shortly (mid 2007) a He cryostat with a supraconducting magnet will be installed around the laser beam lines.Coherent 2,5 mJ Amplifier + Light-Conversion OPA + Home made THz Sourcemodel Legend USP-HP, TOPAS+DFG |
|
|
LOMA Bordeaux |
PL
|
Time and frequency-resolved spectroscopy of single absorbing nano-object : Absolute absorption cross section measurement and spectroscopy in the visible range ? sensitivity: 5 nm2 Femtosecond studies - 100fs resolution (home made system) |
|
|