ICMAB Barcelona |
Moessbauer
|
Powder, film and liquid (frozen during experiment) specimens. Expertise in magnetic nanoparticles measurements. 293K to 4,2K, Co57 |
|
|
ICMAB Barcelona |
SEM
|
Philips 515: Old equipment dedicated to routine work of first appraisal of morphological features of samples. no EDS |
|
|
ICMAB Barcelona |
TEM
|
TEM 120Kv JEOL 1210 (with EDS) |
|
|
ICMAB Barcelona |
XRD
|
ENRAF NONIUS CAD4: Single-crystal XRD 293K |
|
|
ICMAB Barcelona |
SQUID
|
QUANTUM DESIGN MPMS-XL7, MPMS-5: 2 SQUID magnetometers (5 & 7 Tesla) with continuous low temperature control (1.8K-390K). Oven option (400-800K), RSO option. AC susceptibility measurements |
|
|
ICMAB Barcelona |
µXRD
|
BRUKER-AXS D8 diffractometer with GADDS; MicroXRD (from 2006) 50 m lateral res. (D8 with GADDS), CuKa; Standard microdiffraction measurements on flat samples |
|
|
ICG Montpellier |
NMR
|
Solid-state NMR BRUKER FT AM 400 |
|
|
ICG Montpellier |
IR
|
FTIR PERKIN ELMER 1000 |
|
|
ICG Montpellier |
SEM
|
SEM JEOL 6300F |
|
|
ICG Montpellier |
IR
|
FTIR Perkin-Elmer Spectrum 2000 (ATR, DRIFT) |
|
|
ICG Montpellier |
IR
|
FTIR Nicolet Avatar 320 (transmission, DRIFT, Grazing incidence) |
|
|
ICG Montpellier |
TGA
|
TGA/DTA Netzsch Luxx STA 409 |
|
|
ICG Montpellier |
Sorption
|
Sorptometer Micromeritics ASAP 2010 |
|
|
ICG Montpellier |
Sorption
|
N2 and Argon adsorption-desorption Micromeritics Asap |
|
|
ICG Montpellier |
PL
|
fluorescence (Photoluminiscence) spectroscopy: Home built equipment |
|
|
ICG Montpellier |
TGA
|
TGA, DSC Setaram TG DSC 111 |
|
|
ICG Montpellier |
IR
|
diffuse reflectance IR spectroscopy Bruker |
|
|
ICG Montpellier |
UV-Vis Spectroscopy
|
diffuse reflectance UV spectroscopy Perkin Elmer Lamda 14 |
|
|
ICG Montpellier |
Particle Sizer
|
Light Scattering Malvern 4800 |
|
|
ICG Montpellier |
FFF
|
Field Flow Fractionation Wiatt |
|
|
CHEMISTRY St Andrews |
NMR
|
Solid State NMR 500 MHz, wide spectral range, H-2 NMR |
|
|
CHEMISTRY St Andrews |
XRD
|
Single crystal diffraction: Copper rotating anode source, ccd detector, suitable for small crystals |
|
|
CHEMISTRY St Andrews |
Sorption
|
Gravimetric adsorption (automated) Adsorption of hydrocarbon vapors |
|
|
CHEMISTRY St Andrews |
TEM
|
200 kV TEM mesoporous solids |
|
|
MATCHEM Liverpool |
PressSynth
|
High pressure synthesis: Rockland Research multianvil with Walker module to 6 GPa, 1200 C: currently BN is the containment medium though we are developing metal containers suitable for use with oxides |
|
|